System Status: Operational
AfricaAsiaIndian Ocean
Lat −20.5484°
Lon +57.5522°
Hub MU
UMEL Mobile Suppression Unit · Field Deployed

The Architecture
of Total Protection

Advanced fire suppression systems for critical infrastructure — engineered by Pri-Safety, deployed on the ground by Universal Mining Equipment Ltd. We bridge world-class engineering with the brutal realities of your local operating environment.

40+Countries
2005Since
ISO 9001Certified
40+Countries Deployed
2005Innovating Since
ISO 9001Certified
FK-5112Armed
CAFSReady
10 MPaWater Mist
UplinkStable
01 / Capabilities

Three Systems.
One Architecture.

Fire never plays fair. Our architecture matches the threat — clean gas for sensitive electronics, foam for volatile escalation, mist for industrial heat. Engineered, certified, deployed.

Cap / 01

Clean Gas

FK-5112
FK-5112 clean gas system installed in a data centre Data Centre · Protected

Zero-damage total flooding for sensitive electronics. Engineered for data centres, medical facilities and petrochemical control rooms.

Zero Residue Non-Conductive Halon Substitute
Cap / 02

CAFS

Compressed Air Foam
CAFS compressed air foam discharging from a red nozzle First Response · 0:30

Rapid-response containment for fast-growing chemical and fuel fires. The bridge between ignition and professional fire response.

2–10 min Window On-Site Operator Foam Blanket
Cap / 03

Water Mist

High-Pressure · 10 MPa
High-pressure water mist nozzle spraying from a red industrial pipe Mining · Industrial

Heavy-duty, modular heat extraction for industrial machinery, mining and continuous-operation environments. Built for brutal realities.

10 MPa 70/80/90 L Modular
02 / The Tactical Arsenal

Specs. Without
The Sales Pitch.

Each system is matched to a specific failure mode. Below is exactly what each does — and what it doesn't.

Sys · 01 · FK-5112

The Zero-Harm
Guardian

Dodecafluoro-2-methylpentan-3-one. A total flooding automatic suppression agent engineered for absolute preservation of active circuitry. 100% non-conductive, zero residue, sustainable Halon 1301 substitute.

4.5%Extinguish Concentration
Sys · 02 · CAFS

The Critical
First Responder

Compressed Air Foam Systems engineered for the escalation gap. Immediate, suffocating containment of petrol, chemical and fuel fires — without requiring specialised firefighter training.

0:30To Deploy
Sys · 03 · Water Mist

Heavy-Duty Heat
Extraction

Extreme mechanical pressure fractures water into micro-droplets — increasing surface area exponentially to absorb and extract massive thermal energy. Non-conductive across automated belts.

10 MPaWorking Pressure
03 / Anatomy of FK-5112

Engineered for
Absolute Preservation.

The threat vector is not the fire — it is the response. Water and foam guarantee hardware ruin and data loss. FK-5112 is the protocol when downtime is not an option.

Industrial machinery — FK-5112 protected asset UMEL · Field Deployment
// FK-5112 Profile

Total Flooding.
Zero Residue.

FK-5112 discharges as an inert vapour. It reaches a 4.5% extinguish concentration in seconds, smothers the oxygen envelope, and leaves no liquid behind. Active circuitry continues to run.

It is safe at twice the design point (NOAEL @ 10%), GWP equals 1, ODP equals 0 — the sustainable Halon substitute for occupied operational spaces.

Request Datasheet
Sustainable
GWP = 1 · ODP = 0

The ultimate Halon 1301 substitute.

Equipment
100% Non-Conductive

Zero residue post-discharge. Active circuitry remains safe.

Personnel
NOAEL @ 10%

Safe for highly occupied operational spaces.

Response
Ultra-Fast Deploy

Dramatically reduces critical infrastructure downtime.

// CAFS Bridge Window

The 0:30 → 10:00
Window.

Fire intensity spikes exponentially. CAFS holds the line until municipal response arrives to a contained scene — not a structural loss.

Phase 01
Ignition · 0:00
→
Phase 02 · CAFS
0:30 → 10:00 · Active Intervention
→
Phase 03
Municipal Handover · 10:00+
Fire IntensityTime →
04 / Global Pedigree · Local Execution

The Manufacturer.
The Vanguard.

A two-tier partnership. Pri-Safety designs and certifies. UMEL adapts, deploys and remains accountable on the ground.

// The Manufacturer

Pri-Safety

Heritage

Innovating critical infrastructure protection since 2005.

Reach

Proven and actively deployed in 40+ countries globally.

Standards

ISO 9001:2015 Certified Manufacturing · UL · FM · CE · UN ECE R107.

// The Vanguard

UMEL

Adaptation

Bespoke environmental auditing and hardware tailoring for each site.

Deployment

Rapid regional logistics and deployment orchestration.

Accountability

Direct on-the-ground project management and integration.

// Certifications

✓ISO 9001:2015
✓UL Listed
✓FM Approved
✓CE Marked
✓CCC Certified
✓UN ECE R107

Engineering is just the baseline.
Execution is everything.

— The UMEL Doctrine
05 / Service Excellence Lifecycle

Design. Build.
Train. Sustain.

Protection is not a product — it's a continuous operational discipline. UMEL owns every phase of the lifecycle.

Phase 01

Solution Design

Deep environmental auditing, hazard calculation and spatial risk assessment by regional experts.

Phase 02

Customisation

Tailoring hardware networks — pipe routing, modular capacities, activation thresholds — to architectural layouts.

Phase 03

Technology Training

Equipping your ground teams with operational mastery — crucial for rapid-response systems like CAFS.

Phase 04

After-Sales Support

Unwavering, responsive maintenance and pressure-testing across our entire continental footprint.

06 / Localised Command · Continental Reach

The Expert
On The Ground.

UMEL is the definitive regional authority for professional fire systems across Africa, Asia and the Indian Ocean islands. We bridge world-class engineering with local operating realities.

54+Nations Coverage
HQ · MUAfrica Business Centre
RapidLocalised Deployment
24/7Region-Wide Support
UMEL deployment territory — Africa, Asia and the Indian Ocean, headquartered in Mauritius
Active Deployment Zone
−20.5° S · +57.5° E
Coverage Zone

Africa, Asia and the Indian Ocean islands — bridging world-class engineering with the brutal realities of your local operating environment.

Sectors Served
  • · Data Centres
  • · Mining & Heavy Industry
  • · Petrochemical Plants
  • · Medical Facilities
  • · Manufacturing Lines
07 / Ready To Deploy

Bring The Architecture
On Site.

Tell us what you're protecting. A regional engineer will respond within one business day with a preliminary risk read and a no-obligation site visit window.

Office
Universal Mining Equipment LtdAfrica Business Centre · 1st Floor
Unity House, 51 Rue du Savoir
Cybercity, Ebene · Mauritius
Office Line
+230 468 7372Mon–Fri · 08:30–17:30 MUT
Mobile
+230 5806 060624/7 on-call dispatch
Email
sales@umel.muBrief intake · 1 business day reply